Characteristics of Bolt-Clamped Langevin Type Ultrasonic Transducer with Square Radiating Surface

Autor: Hisao Banno, Haruo Yamamori, Kanji Ohya, Toshiharu Ito
Rok vydání: 1990
Předmět:
Zdroj: Japanese Journal of Applied Physics. 29:167
ISSN: 1347-4065
0021-4922
DOI: 10.7567/jjaps.29s1.167
Popis: A bolt-clamped Langevin type ultrasonic transducer having a square radiating surface was studied in relationship between amplitude distribution on the radiating surface and front-block size. A chamfered transducer with a 45 mm square surface showed uniform vibration amplitude distribution on its radiating surface. An immersible ultrasonic cleaner installed with optimized transducers was verified in terms of sound pressure in water.