Characteristics of Bolt-Clamped Langevin Type Ultrasonic Transducer with Square Radiating Surface
Autor: | Hisao Banno, Haruo Yamamori, Kanji Ohya, Toshiharu Ito |
---|---|
Rok vydání: | 1990 |
Předmět: | |
Zdroj: | Japanese Journal of Applied Physics. 29:167 |
ISSN: | 1347-4065 0021-4922 |
DOI: | 10.7567/jjaps.29s1.167 |
Popis: | A bolt-clamped Langevin type ultrasonic transducer having a square radiating surface was studied in relationship between amplitude distribution on the radiating surface and front-block size. A chamfered transducer with a 45 mm square surface showed uniform vibration amplitude distribution on its radiating surface. An immersible ultrasonic cleaner installed with optimized transducers was verified in terms of sound pressure in water. |
Databáze: | OpenAIRE |