Popis: |
This study used ceramic membrane technology to concentrate tungsten fine particles for its inefficient recycling issue. Factors affecting the membrane concentration test were discussed, and the results show that: under the feed flow of 7000 mL/min, concentration time of 3 hours, and concentration liquid flow of 500 mL/min, it is the optimal effect of ceramic membrane concentration tungsten fine particle, which the interception rate reaches more than 99%, the membrane permeation flux can be nearly reach 470mL/(min×1099cm2) above, and concentrate concentration can be basically stable at around 29% . Ceramic membrane flux recovery rate can be as high as 93% by 7 minutes backwashing firstly and then 2 minutes forward cleaning. |