Performance Evaluation of Transmission Line Protection Characteristics with DSTATCOM Implementation
Autor: | Yasar Khan, Sanaullah Ahmad, Khalid Mahmood |
---|---|
Rok vydání: | 2017 |
Předmět: |
General Computer Science
Computer science Thyristor controlled reactor Thyristor Static VAR compensator AC power Inrush current law.invention Electric power system Capacitor Electric power transmission Flexible AC transmission system Transmission (mechanics) law Thyristor switched capacitor Harmonic Electronic engineering Maximum power transfer theorem Induction motor Voltage |
Zdroj: | International Journal of Advanced Computer Science and Applications. 8 |
ISSN: | 2156-5570 2158-107X |
DOI: | 10.14569/ijacsa.2017.080812 |
Popis: | To meet with the ever-enhancing load demands, new transmission lines should be bolted-on in the existing power system but the economic and environmental concerns are major constraints to this addition. Hence utilities have to rely on the existent power system infrastructure with some modifications. To enhance controllability and boost power transfer potential of the existing power system the use of Flexible Alternating Current Transmission System (FACTS) device is the most viable modification. FACTS devices include Static VAR Compensator (SVC), thyristor controlled series capacitor (TCSC), Thyristor Controlled Reactor (TCR), Thyristor Switched Capacitor (TSC) and Self Commutated VAR compensators i.e. Static Synchronous Compensator (DSTATCOM). Among the FACTS devices, DSTATCOM is the most feasible choice because of its capability to furnish both leading and lagging reactive power, faster response time in comparison with others, smaller harmonic content, inrush current generation is minimum and the dynamic performance with variations of voltage is quite good. DSTATCOM has the ability to have effective control over various issues concerning AC power transmission. However, the Parameters of the protection devices in the present power system are set without taking into account the reaction of these FACTS devices. So in order to ascertain stability and reliability of power system, reaction of FACTS devices with the existent protection schemes must be thoroughly investigated. This paper aims to explore the deviations in the performance characteristics of transmission line protection due to installation of DSTATCOM on a 220KV EHV transmission line using theoretical as well as MATLAB/SIMULINK simulation models. The dynamic performance of a DSTATCOM connected to an existing transmission line system is evaluated when large industrial induction motor is started and voltage sags are introduced. |
Databáze: | OpenAIRE |
Externí odkaz: |