Electrostatic Deflectors for Luminosity Measurements at the Cern pp Collider
Autor: | R. Guinand, R Bonvin, R Dubois, W. Kalbreier, Karl Heinz Kissler, N Garrel |
---|---|
Rok vydání: | 1983 |
Předmět: | |
Zdroj: | IEEE Transactions on Electrical Insulation. :322-324 |
ISSN: | 0018-9367 |
DOI: | 10.1109/tei.1983.298620 |
Popis: | Electrostatic deflectors are used in the CERN SPS Collider to separate the orbits of protons and antiprotons. The total installation comprises 4 tanks, 3 m long each, with a vacuum of 10-8 Pa after baking. The operating electric field is 50 kV/cm across a gap of 4 cm, between 3 m long titanium electrodes; the spark rate does not exceed 2 per 24 hours. The construction, the HV circuit, and the performances of the separators are described in this paper. |
Databáze: | OpenAIRE |
Externí odkaz: |