Postdelivery levels of anti-D IgG prophylaxis in D- mothers depend on maternal body weight

Autor: Simon Panzer, Karl Philipp, Brigitte Woelfer, K. Schuchter, Erich Hafner, Michael Janisiw
Rok vydání: 2004
Předmět:
Zdroj: Transfusion. 44:512-517
ISSN: 0041-1132
DOI: 10.1111/j.1537-2995.2004.03287.x
Popis: BACKGROUND: Current recommendations for anti-D prophylaxis for women who deliver a D+ offspring vary from country to country, and the introduction of new reagents require pharmacokinetic studies that show serum levels after the injection. Serum levels of anti-D may depend on the maternal body mass index (BMI). STUDY DESIGN AND METHODS: Serum concen-trations of total anti-D IgG and IgG1-4 subclasses were determined by flow cytometry in 26 D– women, who had received prophylaxis after delivery of a D+ offspring. Blood samples were drawn on Days 1, 2, 3, and 14 after injection, and the BMI was recorded. RESULTS: Anti-D levels increased continuously in all women during the first 3 days. The increase was significantly affected by the BMI if higher than 27 kg per m2 (p < 0.001). The higher the BMI, the less was the increase of serum anti-D. Mean peak levels 72 hours after injection was 89 ng per mL in lean women, but estimated levels were 28 to 60 percent lower in women with a BMI of 28 to 40 kg per m2. The effect of a BMI higher than 27 kg per m2 on anti-D was not gradual but progressive. Similarly, the BMI affected serum concentrations of anti-D subclasses IgG1-4 (p < 0.001). CONCLUSION: The BMI needs consideration for the adjustment of the dosage of anti-D, provided its bio- availability to suppress alloimmunization is reflected by measurable amounts in the serum.
Databáze: OpenAIRE