Endoprothetischer Ersatz der nicht rekonstruierbaren Radiuskopffraktur (Mason III und IV) mit der bipolaren Radiuskopfprothese nach Judet - Klinische Ergebnisse
Autor: | O. Weber, C. D. Wirtz, N. Striepens, M. C. Müller, Christof Burger |
---|---|
Rok vydání: | 2008 |
Předmět: |
medicine.medical_specialty
biology business.industry medicine.medical_treatment Elbow Joint stability medicine.disease Radial head prosthesis biology.organism_classification Prosthesis Surgery Valgus medicine.anatomical_structure medicine Deformity Dash score Orthopedics and Sports Medicine Heterotopic ossification medicine.symptom business |
Zdroj: | Zeitschrift für Orthopädie und Unfallchirurgie. 146:218-226 |
ISSN: | 1864-6743 1864-6697 |
DOI: | 10.1055/s-2008-1038333 |
Popis: | AIM Long-term results after resection of comminuted fractures of the radial head (Mason III and IV) may lead to valgus elbow instability, radius proximalisation and rotatory instability. Radial head replacement has been used to prevent and treat these complications. The aim of this study was to define the value of the bipolar radial head prosthesis of Judet for treating comminuted fractures of the radial head. METHOD Over a 5-year period, 14 radial head prosthesis were implanted in 12 patients. Retrospectively, we studied the clinical and radiological results. RESULTS Eleven patients with thirteen implants were analysed at a mean follow-up of 33.4 +/- 20.4 months. In all patients, the elbow was stable. Subjectively, we found good and excellent results with one exception. Compared to the pre-trauma status, the subjective rate was 78 +/- 12 %. According to the score of Radin and Riseborough, five of the results were found to be good and eight to be fair. According to the Broberg and Morrey score, one result was found to be very good, seven to be good and five to be fair. The mean DASH score was 10.2 +/- 10.1 points. Two temporary nerve lesions were observed. CONCLUSION In comminuted fractures of the radial head (Mason III and IV), bipolar radial head replacement with the Judet prosthesis leads subjectively to very good and good and functionally to good and fair results on the medium-term view. Joint stability is achieved and secondary complications like valgus elbow deformity and proximal radial migration are prevented. Patients must be informed about the possibility of temporary nerve lesions, heterotopic ossification causing limitation of motion and the lack of long-term results. |
Databáze: | OpenAIRE |
Externí odkaz: |