Simultaneous Analysis of T-2 Toxin and HT-2 Toxin by an Indirect Enzyme-Linked Immunosorbent Assay

Autor: Titan S L Fan, Yi-Chun Xu, Fun S. Chu
Rok vydání: 1987
Předmět:
Zdroj: Journal of AOAC INTERNATIONAL. 70:657-661
ISSN: 0004-5756
DOI: 10.1093/jaoac/70.4.657
Popis: An indirect enzyme-linked immunosorbent assay (ELISA) for the detection of HT-2 toxin in the presence or absence of T-2 toxin is described. In the indirect ELISA, the relative cross-reactivities of antibodies against T-2 toxin (anti-T-2) with T-2 toxin and HT-2 toxin were 1 and 0.1, whereas anti-HT-2 cross-reactivities with T-2 toxin and HT-2 toxin were 0.33 and 1, respectively. Using such relationships, a formula was established that could be used to calculate the individual toxin concentration in a mixed sample after experimentally analyzing for T-2 and HT-2 toxins in the 2 indirect ELISAs. This method was tested by analyzing urine samples spiked with HT-2 toxin alone and samples spiked with both T-2 toxin and HT-2 toxin. A cleanup protocol for treatment of urine samples before ELISA was also established. The overall analytical recovery of HT-2 toxin when it was added at concentrations of 0.1-10 parts per billion (ppb) to the urine samples was ca 89%. When both T-2 and HT-2 toxins were added to the urine samples at equal concentrations of 0.5 to 5.0 ppb, their recoveries were 112 and 109%, respectively.
Databáze: OpenAIRE