Popis: | The time for recovery of recognition of an optotype presented at a distance of 40 m subsequent to exposure to a flash gun (Eso company, Tettnang; flash energy 200 Ws, duration 1/1000 s; distance 10 m) was studied on 97 subjects aged 20 to 83 years. A Landolt-ring (contrast 1:5, diameter 29 cm), mounted on a disk (diameter 58 cm) which could be rotated in steps of 45 degrees served as a test target. The flash gun could be dimmed down by a red filter (Schott RG 665). The tests were performed at night without additional illumination except the low beam of the car. The flash gun was foveally fixated. After a white flash, a period of 93.1 s +/- 48.6 s (MEAN +/- SD) passed before the optotype could be recognized correctly again. By adding the red filter in front of the flash gun the recovery time could be shortened significantly (p Language: de |