Bei stationärer Aufnahme korrekte Inhalationstechnik prüfen – unabhängig von der Art des verwendeten Systems
Autor: | Peter Haidl |
---|---|
Rok vydání: | 2022 |
Zdroj: | Kompass Pneumologie. 10:296-297 |
ISSN: | 2296-0317 2296-0368 |
DOI: | 10.1159/000527243 |
Popis: | For optimal drug delivery, dry powder inhalers (DPIs) depend on the patient’s peak inspiratory flow (PIF) and the internal resistance of the device to create turbulent energy and disaggregate the powder. A suboptimal PIF may lead to ineffective drug inhalation into the lungs. Our objective was to report the prevalence of suboptimal PIF in patients with COPD hospitalized for any reason using 1 or more DPIs. In this real-world, observational, single-site, retrospective study, PIF was measured for each DPI using the In-Check™ DIAL set to match the resistance of the DPI used by each patient. PIFs |
Databáze: | OpenAIRE |