High-intensity focused ultrasound cyclo-coagulation: a prospective study from a tertiary center
Autor: | L. Abegao Pinto, David Cordeiro Sousa, Carlos Marques-Neves, N. Pinto Ferreira |
---|---|
Rok vydání: | 2017 |
Předmět: |
Intraocular pressure
medicine.medical_specialty genetic structures business.industry medicine.medical_treatment Glaucoma General Medicine medicine.disease eye diseases Focused ultrasound High-intensity focused ultrasound 03 medical and health sciences Ophthalmology Safety profile 0302 clinical medicine Hifu treatment 030221 ophthalmology & optometry medicine sense organs business Prospective cohort study Adverse effect 030217 neurology & neurosurgery |
Zdroj: | Acta Ophthalmologica. 95 |
ISSN: | 1755-375X |
DOI: | 10.1111/j.1755-3768.2017.03562 |
Popis: | Purpose High-intensity focused ultrasound (HIFU) technology aims to achieve selective coagulation of the cilliary body, thus reducing aqueous humor production and lowering intraocular pressure (IOP). This study evaluated safety and efficacy of HIFU cyclo-coagulation using EyeOP-1® device in 44 glaucoma patients. Methods Glaucoma patients with uncontrolled IOP despite optimal medication were scheduled for HIFU treatment and followed for 12 months. The primary efficacy and safety outcomes were IOP reduction and major adverse events, respectively. Statistical analyses were performed using STATA v14.1. Results Fourty-four patients (23 male) with a mean age of 70 ± 15 years were studied. Mean preoperative IOP reduced from 26.6 ± 3.8 mmHg to 17.7 ± 4.3 mm Hg at month 6 and 17.4 ± 3.3 mm Hg after 12 months (P |
Databáze: | OpenAIRE |
Externí odkaz: |