Purification of Phenolic Wastewater Using Aerobic Bio-oxidation Combined with Activated Carbon Treatment and Ozonation

Autor: Andres Viiroja, Oliver Järvik, Juha Kallas, Inna Kamenev
Rok vydání: 2010
Předmět:
Zdroj: Ozone: Science & Engineering. 32:417-423
ISSN: 1547-6545
0191-9512
DOI: 10.1080/01919512.2010.522957
Popis: The combined process – aerobic bio-oxidation with activated carbon addition and ozonation was studied (ABO/AC/O3). The performance of the process was compared with conventional aerobic bio-oxidation (ABO). The studies were carried out in two continuous and periodic reactors to evaluate the purification efficiencies (in terms of COD, BOD and resorcinols removal), excess sludge generation and stability of the bioreactors against shock loadings. The parameters in continuous combined process were as follows: organics loading was 620 mgCOD/(day·L), activated carbon concentration 1g/L and ozone dose 2.45 mgO3/L (mg ozone per liter of treated water). In periodic reactors the combined process was studied at lower activated carbon concentration and ozone dose (0.3 g/L and 0.57 mg/L respectively). The results indicated that compared with conventional ABO, the co-effect of AC addition and short-termed (less than 1 week) or intermittent ozonation improved the removal of COD and BOD, while the longer period of ozonati...
Databáze: OpenAIRE
Nepřihlášeným uživatelům se plný text nezobrazuje