Autor: Blaine F. Severin, Peter F. Roessler, Jyotirmoy Dey
Rok vydání: 1999
Předmět:
Zdroj: Quantitative Microbiology. 1:111-136
ISSN: 1388-3593
DOI: 10.1023/a:1010032524244
Popis: A UV reactor with an annular design, a total liquid volume of 460[emsp4 ]ml, and outfitted with a single lamp with 1690[emsp4 ]mW of germicidal power was tested. Coliphage MS2 was used as a bioactinometer to measure the UV dose at a flow rate of 56.7[emsp4 ]ml/sec in water with a very low absorbance. The Beers Law coefficient was A100.003. The measured dose (MS2 bioactinometry) was 35.2±1.1[emsp4 ]mW-sec/cm2.