SIMULATION OF THE MECHANICAL STIMULATION EFFECT ON THE PEN JUNCTION BETWEEN BONE AND PELVIC BASED ON FINITE ELEMENT METHODS

Autor: Khusnul Yakin
Rok vydání: 2020
Předmět:
Zdroj: Jurnal Neutrino. 12:65-70
ISSN: 2460-5999
1979-6374
DOI: 10.18860/neu.v12i2.9243
Popis: Bone remodeling process influenced by cells osteoblast and osteoclast. The remodeling of cortical and trabecular influenced by mechanical stimuli. In this study, cortical and trabecular bones of 25 years old humans were observed, and the result was the cortical bone has the average Young’s modulo 17.9 MPa with the Poisson’s ratio of 0.4. Trabecular bone has the average Young’s modulo of 13 MPa and the Poisson’s ratio of 0.5. The metal orthopedic bone screw, which has used in this research simulation, was is a Titanium screw. The screw has Young’s modulo of 110 GPa and the Poisson’s ratio of 0.29. The results of the simulation of femoral bone elasticity limit with standing activity at the age of 25 were found in the left femur of 112.9416 MPa and the right femur of 115.5134 MPa. The limit of elasticity of the femur due to walking was found in the left femur of 115.2166 MPa with an accuracy of 94.11% and the right femur of 117.6692 MPa.