Drying and heating of the insulating walls of coke-battery buttresses
Autor: | N. G. Chura, P. V. Lipunov, V. I. Markov, S. V. Motrich |
---|---|
Rok vydání: | 2014 |
Předmět: | |
Zdroj: | Coke and Chemistry. 57:422-424 |
ISSN: | 1934-8398 1068-364X |
DOI: | 10.3103/s1068364x14110064 |
Popis: | The reconstruction of coke battery 1 at Isfahan Steel Works is considered. The structure of the Dinas component in the insulating walls at coke battery 1 with a PVR-51 system is described; this battery has bottom supply of the heating gas; the useful volume of a single oven is 27.3 m3. The research shows that drying and heating of the Dinas component by a burner with a protective casing protects the refractory surface of the insulating wall from an open flame during heating from 20 to 500°C. |
Databáze: | OpenAIRE |