Uncommon cause of paradoxical low-flow low-gradient severe aortic stenosis: easy to underestimate, difficult to diagnose

Autor: Yuji Ikari, Shoko Doi, Gaku Nakazawa, Yohei Ohno
Rok vydání: 2016
Předmět:
Zdroj: European Heart Journal. 37:2678-2678
ISSN: 1522-9645
0195-668X
Popis: An 87-year-old man was admitted due to congestive heart failure. He had a history of coronary artery bypass surgery, chronic atrial fibrillation, chronic kidney disease, and chronic obstructive pulmonary disease on home oxygen therapy. Transthoracic echocardiography showed preserved left ventricular ejection fraction (LVEF = 54%) with no remarkable LV hypertrophy but low-gradient severe aortic stenosis (AS) (mean pressure gradient [MPG] 28 mm Hg, aortic valve area [AVA] 0.7 cm2, Panel A ) with severely calcified and reduced mobility aortic …