Geometric calibration based on B-spline with multi-parameter and color correction based on transition template and decay function
Autor: | Ya-ting Xue, Min Jiang, Yao-jie Chen |
---|---|
Rok vydání: | 2019 |
Předmět: |
Computer Networks and Communications
Computer science ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION Stereoscopy 02 engineering and technology Luminance law.invention law Position (vector) Chromatic aberration 0202 electrical engineering electronic engineering information engineering Media Technology Computer vision Projection (set theory) ComputingMethodologies_COMPUTERGRAPHICS business.industry Color correction B-spline 020207 software engineering Projector Hardware and Architecture Control point Artificial intelligence business Texture mapping Software Surface reconstruction |
Zdroj: | Multimedia Tools and Applications. 79:4333-4346 |
ISSN: | 1573-7721 1380-7501 |
DOI: | 10.1007/s11042-018-6930-4 |
Popis: | To achieve low-cost and fast multi-channel surface projection geometric correction, the quadratic quasi-uniform B-spline surface is used to reconstruct the deformation screen, and the coordinates of the boundary mesh node are calculated as the texture mapping vertex coordinates by adjusting the position of the control point. On the DirectX platform, the main desktop image is obtained through frame buffer copy, by adjusting the shape parameters and moving the control points as a whole, the multi-projection screen is corrected and the coordinates are saved to realize the surface reconstruction. Compared with the no-parameter curve, by adding a plurality of shape parameters, the distance and the relationship between the control point and the curve are more precisely adjusted, and better correction can be realized. Then, feature image projection is performed between adjacent channels, and the color template is calculated according to the collected color information to apply to a video frame of one channel, thereby eliminating chromatic aberration caused by different projector lamp problems. Finally, a smooth luminance decay function is used to attenuate the highlights appearing in overlapping areas between adjacent channels. The experimental results of the two-channel stereoscopic projection system show that the method is simple and highly efficient, and it has lower requirements for equipment, which is easy to operate in the adjustment process, and has strong adaptability to the engineering environment. |
Databáze: | OpenAIRE |
Externí odkaz: |