Spatial Resolution of the PEP-4 Time Projection Chamber

Autor: B. C. Shen, K. A. Derby, D. H. Badtke, R. W. Kenney, A. Pevsner, H. Iwasaki, F. R. Rouse, Barry Blumenfeld, O. I. Dahl, J. E. Huth, A. Barbaro-Galtieri, M. Alston-Garnjost, K. Maruyama, L. Madansky, J. Chiba, J. Hylen, B. A. Barnett, R. I. Koda, Hiroaki Aihara, R. van Tyen, R. R. Kofler, J. M. Hauptman, H. K. Ticho, B. Gabioud, P. S. Martin, T. Fujii, R. J. Madaras, W. A. Wenzel, C. S. Lindsey, S. O. Melnikoff, M. E. Zeller, M. L. Stevenson, X-Q. Lu, M. D. Shapiro, J. G. Layter, A. D. Bross, J. N. Marx, Mitchell Wayne, H. Videau, D. R. Nygren, W. Moses, R. F. vanDaalen Wetters, J. W. Gary, P. Delpierre, P. J. Oddone, N. J. Hadley, N. Toge, J. A. Bakken, M. Yamauchi, G. Shapiro, Ronald Madaras, P. Nemethy, A. V. Barnes, R. R. Ross, H. Hilke, M. Pripstein, J. A. J. Matthews, G. J. Van Dalen, G. R. Lynch, Allan G Clark, D. H. Stork, P. R. Robrish, D. L. Fancher, J. Mallet, D. A. Park, O. Chamberlain, R. Majka, S. C. Loken, W. C. Carithers, P. H. Eberhard, C.Y. Chien, K. K. Kwong, H. Fujii, W-M. Zhang, M. T. Ronan, T. Kamae, W. E. Slater, C. D. Buchanan, M. Urban, W. Gorn, B. Heck, C. T. Day, L. T. Kerth
Rok vydání: 1983
Předmět:
Zdroj: IEEE Transactions on Nuclear Science. 30:76-81
ISSN: 0018-9499
DOI: 10.1109/tns.1983.4332223
Popis: The spatial resolution and response of the segmented cathode pads of the PEP-4 TPC have been measured with data taken at 8.5 atmospheres of 80% Argon-20% Methane gas with a 4kG magnetic field. The dependence of the spatial resolution and pad response on drift distance and track-anode crossing angle is presented.
Databáze: OpenAIRE