Computer science Numerical analysis Finite difference 020206 networking & telecommunications Scalar potential 02 engineering and technology 030218 nuclear medicine & medical imaging 03 medical and health sciences 0302 clinical medicine 99th percentile Electric field 0202 electrical engineering electronic engineering information engineering Dosimetry Wireless power transfer Simulation |
Zdroj: | 2019 Joint International Symposium on Electromagnetic Compatibility, Sapporo and Asia-Pacific International Symposium on Electromagnetic Compatibility (EMC Sapporo/APEMC). |
DOI: | 10.23919/emctokyo.2019.8893818 |
Popis: | This paper provides a dosimetry model of a 3 dimensional (3-D) box-shaped open-structured wireless power transfer (WPT) system for mobile devices. The induced electric field in the forearm and hand of an adult male model are evaluated at 6.78 MHz with 99th percentile values as prescribed by ICNIRP. Numerical method of scalar potential finite difference (SPFD) is adopted for the dosimetry analysis; different positions of the forearm with respect to the charging system are investigated. This paper presents an explicit dosimetry model and analysis of the electric field in human forearm for a 3-D box-shaped WPT system. |