Popis: |
A new turbine cascade has been constructed that is designed to investigate the performance of actual nozzle guide vane hardware at temperatures representative of modern gas turbine engines. The facility is designed to investigate internal and external deposition, analyze the effectiveness of new cooling techniques, characterize material systems such as metal substrates or coatings, and assess the aerodynamic performance of a vane. The results presented here are the first results obtained in this new facility. External deposition on cooled CFM56 nozzle guide vanes has been explored at inlet temperatures of 1090° C, 1265° C, and 1350° C. Results at 1090° C have been compared to similar results in a previous facility. External deposition tests at temperatures greater than 1100° C on actual turbine hardware have not been reported publicly prior to this paper. These results show that deposition is concentrated at the stagnation line at all three inlet conditions. The amount of deposition on the vane pressure surface increased with increasing inlet temperatures. |