Autor: |
Ana Carolina Caldas Vilas Bôas, Gabriel Jorge, Júlio Márcio Silveira E Silva, Rafael Familiar Solano, Ana Paula França de Souza |
Rok vydání: |
2019 |
Předmět: |
|
Zdroj: |
Volume 5B: Pipelines, Risers, and Subsea Systems. |
DOI: |
10.1115/omae2019-95145 |
Popis: |
This work addresses pure collapse experimental tests conducted with DNVGL-450 seamless pipe samples with D/t ratio equal 7.7 and 8.6. Interesting results were achieved, showing that the pipes presented a significant plastic deformation before collapse. There is a limited amount of available technical publications addressing real scale tests with thicker pipes, D/t < 20, that makes the results available quite important for the better understanding of thicker pipes. FEM was conducted and a good correlation with experimental test results were obtained. The experimental and numerical results were correlated with the DNVGL-ST-F101 pure collapse limit state equation, one of the main the rule used in the design of ultra-deep-water subsea pipelines. Conclusions and recommendations for future work based on the results achieved are presented. |
Databáze: |
OpenAIRE |