Study of inception point, void fraction and pressure over pooled stepped spillways using Flow-3D
Autor: | Afshin Eghbalzadeh, Khosro Morovati |
---|---|
Rok vydání: | 2018 |
Předmět: |
Spillway
Computer simulation Applied Mathematics Mechanical Engineering 0208 environmental biotechnology Flow (psychology) Stepped spillway 02 engineering and technology Mechanics 01 natural sciences 010305 fluids & plasmas 020801 environmental engineering Computer Science Applications Mechanics of Materials Cavitation 0103 physical sciences Point location Crest Porosity Geology |
Zdroj: | International Journal of Numerical Methods for Heat & Fluid Flow. 28:982-998 |
ISSN: | 0961-5539 |
DOI: | 10.1108/hff-03-2017-0112 |
Popis: | Purpose While many stepped spillways geometry design guidelines were developed for flat steps, designing pooled steps might be an appropriate alternative to spillways working more efficiency. This paper aims to deal with the inception point of air-entrainment and void fraction in the different height of the pools. Following that, pressure distribution was evaluated in aerated and non-aerated regions under the effect of different heights of the pools and slopes through the use of the FLOW-3D software. Comparison of obtained numerical results with experimental ones was in good agreement for all discharges used in this study. Pools height had the insignificant effect on the inception point location. The value of void fraction was more affected in lower discharges in comparison with higher ones. Negative pressure was not seen over the crest of spillway (non-aerated region), and the maximum pressure values were obtained for pools with 15 cm height along the crest in each discharge. In all slopes, negative pressure was not formed near the step bed in the pooled and flat stepped spillways. However, negative pressure was formed in more area near the vertical face in the flat stepped spillway compared with the pooled stepped spillway which increases the probability of cavitation phenomenon in the flat stepped chute. Design/methodology/approach A pooled stepped spillway was used in order to evaluate pressure, void fraction, and inception point. Also, different height of the pools was used. Numerical simulation of this study was fulfilled through Flow-3D software. The obtained results indicated that pools can affect two-phase flow characteristics including pressure, void fraction and inception point. Findings Over the crest, negative pressure was not seen. Pressure values were different for all used heights and the maximum ones obtained for 15 cm height. Also, pooled stepped played a more effective role in reducing the negative pressure points compared with flat cases. Inception point location was more affected in nappe and transition flow regimes in comparison with skimming flow regime particularly for 9 and 15 cm heights. Originality/value The research results of Felder et al. (2012a) from the University of Queensland were used to numerically simulate the flow over the pooled stepped spillway. |
Databáze: | OpenAIRE |
Externí odkaz: |