The design and performance of a stereo drift chamber with closely packed planes

Autor: Martin D. Cooper, Richard E. Mischke, James S. Frank, Vernon D. Sandberg, Roger D. Carlini, Howard S. Matis, Richard L. Talaga, John P. Sandoval, Minh Duong-Van, David P. Grosnick, Richard D. Bolton
Rok vydání: 1981
Předmět:
Zdroj: Nuclear Instruments and Methods in Physics Research. 188:275-283
ISSN: 0167-5087
DOI: 10.1016/0029-554x(81)90506-1
Popis: This paper reports on the design and testing of a prototype drift chamber for a forthcoming experiment at LAMPF. This chamber will have small cell spacing and operate at high rates. The prototype chamber consists of cells which are 8 × 10 mm. The planes are separated by 8 mm and are at 20° angles. The r.m.s. resolution of the chamber is about 140 μm. Even at instantaneous rates of 3 kHz · wire −1 · mm −1 , the efficiency is better than 98%. Cross-talk between cells is less than 2%.