Removal of Pu238 from Neptunium Solution by Anion Exchange

Autor: Edward Kyser
Rok vydání: 2003
Předmět:
Popis: A new anion flowsheet for use in HB-Line was tested in the lab with Reillex{trademark} HPQ for removal of Pu{sup 238} contamination from Np. Significant rejection of Pu{sup 238} was observed by washing with 6 to 12 bed volumes (BV) of reductive wash containing reduced nitric acid concentration along with both ferrous sulfamate (FS) and hydrazine. A shortened-height column was utilized in these tests to match changes in the plant equipment. Lab experiments scaled to plant batch sizes of 1500 to 2200 g Np were observed with modest losses for up-flow washing. Down-flow washing was observed to have high losses. The following are recommended conditions for removing Pu{sup 238} from Np solutions by anion exchange in HB-Line: (1) Feed conditions: Up-flow 6.4-8 M HNO{sub 3}, 0.02 M hydrazine, 0.05 M excess FS, less than 5 days storage of solution after FS addition. (2) Reductive Wash conditions: Up-flow 6-12 BV of 6.4 M HNO{sub 3}, 0.05 M FS, 0.05 M hydrazine. 1.8 mL/min/cm{sup 2} flowrate. (3) Decontamination Wash conditions: Up-flow 1-2 BV of 6.4-8 M HNO{sub 3}, no FS, no hydrazine. (4) Elution conditions: Down-flow 0.17 M HNO{sub 3}, 0.05 M hydrazine, no FS.
Databáze: OpenAIRE