Transverse Emittance Measurement of KAERI Linac with Thick Lens Quadrupole Scan
Autor: | Setiniyaz, Sadiq, Baek, In-Hyung, Chae, Moonsik, Gudkov, Boris, Han, Byungheon, Jang, Kyu Ha, Jeong, Young Uk, Kim, Hyun Woo, Miginsky, Sergey, Nam, Jinhee, Park, Sunjeong, Vinokurov, Nikolay |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2015 |
Předmět: | |
DOI: | 10.18429/jacow-fel2015-mop063 |
Popis: | The UED (Ultrafast Electron Diffraction) beamline of KAERI (Korea Atomic Energy Research Institute) WCI (World Class Institute) Center has been completed and successfully commissioned. Transverse emittance of the electron beam was measured at the entrance of the UED chamber with the quadrupole scan technique. In this technique, larger drift distance between the quad and screen is preferred because it gives better thin lens approximation. A space charge dominated beam however, will undergo emittance growth in the long drift caused by the space charge force. We suggest mitigating this growth by introducing quadrupole scan with short drift and without thin lens approximation. We shall discuss the measurement process and results. Proceedings of the 37th International Free Electron Laser Conference, FEL2015, Daejeon, Republic of Korea |
Databáze: | OpenAIRE |
Externí odkaz: |