Simplified determination of serotonin in plasma by liquid chromatography with electrochemical detection

Autor: P C Tagari, D J Boullin, C L Davies
Rok vydání: 1984
Předmět:
Zdroj: Clinical Chemistry. 30:131-135
ISSN: 1530-8561
0009-9147
DOI: 10.1093/clinchem/30.1.131
Popis: This simplified determination of serotonin in human plasma involves "high-performance" liquid chromatography with electrochemical detection. Deproteinated samples of platelet-poor plasma are injected directly into the chromatograph without preliminary chromatographic purification. The limit of quantitative detection of serotonin in plasma is 5 nmol/L (equivalent to 250 fmol injected). Intra- and inter-assay CVs ranged from 5.6% to 7.7% and 3.5% to 14.9%, respectively, for concentrations of serotonin from 0.02 to 10.0 mumol/L. Results agreed well with those by spectrofluorometry, both for plasma standards (r = 0.985, range 100 nmol/L to 100 mumol/L) and for pathological samples obtained from four carcinoid syndrome patients (r = 0.964). The method is also applicable to the concurrent measurement of 5-hydroxytryptophan and 5-hydroxyindoleacetic acid.
Databáze: OpenAIRE