Stability analysis of glass fibre polyamide composite transmission tower
Autor: | Krishanu Gupta, Prasun Chakraborti, Chiranjit Bhowmik |
---|---|
Rok vydání: | 2020 |
Předmět: |
Materials science
Polymers and Plastics Mechanical Engineering Glass fiber Composite number 020101 civil engineering 02 engineering and technology Wind engineering 0201 civil engineering Corrosion 020303 mechanical engineering & transports 0203 mechanical engineering Mechanics of Materials Transmission line Polyamide Materials Chemistry Ceramics and Composites Degradation (geology) Composite material Transmission tower |
Zdroj: | Journal of Reinforced Plastics and Composites. 39:918-931 |
ISSN: | 1530-7964 0731-6844 |
DOI: | 10.1177/0731684420937357 |
Popis: | The cross-sectional degradation of steel transmission tower members due to corrosion has been one of the major issues in the transmission line system. The degradation of appearance of the material has also been seen because of corrosion. Therefore, there is a need for a less corrosive and high strength alternate material for transmission towers. It seems in recent years that alternate materials have been needed to replace steel which have low maintenance cost and good resistance to corrosion. The advantages of composite transmission towers are fire resistant, high stiffness, durability, high strength, moderate ductility, rigidity, easy to assemble and economical. The present study has made an effort to evaluate the performance of composite transmission tower. The glass fibre polyamide composite material has been used as a structural material. First, a finite element tower model of 132 KV has been set up in Structural Analysis and Design Software as glass fibre polyamide structural material as per transmission tower design guidelines (Code for Transmission tower design, IS 802.1.1.1995, Bureau of Indian Standards). Second, all the active loads like wind load on the body, wind load on conducting wires and ground wires, weight of conducting wires, weight of structure, weight of ground wires, weight of insulator and weight of line man with tools are calculated manually as per transmission tower design guidelines and applied in the finite element tower model. The stress distribution of the composite tower model has been simulated in Structural Analysis and Design Software and the results have been analysed. The broken wire condition (if one conductor is broken or earth wire is broken) has been innovatively considered in the present study. Results obtained in this article show that maximum induced stress on transmission tower member is less than the deign strength of glass fibre polyamide composite material. The glass fibre polyamide composite material has been found to be capable to withstand the maximum stresses induced due to different loading conditions considered in the study. |
Databáze: | OpenAIRE |
Externí odkaz: |