A New Pipe Wall Thinning Inspection System

Autor: Houlung Lee, Edward S. Kenney
Rok vydání: 1992
Předmět:
Zdroj: Nuclear Technology. 100:70-78
ISSN: 1943-7471
0029-5450
Popis: By introducing wide-aperture detectors, the efficiency of the conventional Compton scatter imaging technique can be greatly improved. This paper reports on a Monte Carlo method developed to investigate the imaging process of this enhanced Compton imaging technique. Using this technique, a conceptual design of a pipe inspection system has been completed. This system feature the use of dual wide-aperture detectors and a photon source of two energy components. In practice, a source of more than two energy components is allowed. With the inspection system, the inner surface contours of the pipe can be reconstructed in a rather straightforward manner, and the inner surface can be fully mapped. The measured data together with the associated geometry parameters such as size and curvature will serve to provide a two- or three-dimensional contour mapping of the pipe.
Databáze: OpenAIRE