Autor: |
Jiří Voves, Kristina Čabanová, Vladimír Židlík, Petra Matějková, Eva Olšovská, Tomáš Smejkal, Miroslav Havlíček, Roman Madeja |
Rok vydání: |
2022 |
DOI: |
10.21203/rs.3.rs-1374830/v1 |
Popis: |
BackgroundThis case report deals with a twice reoperated patient with right clavicle fracture at the same position within 5 months. The report was divided in to three parts. Case presentationIn the first part the description of both injuries and the methods of their treatment are provided: i) The patient suffered a fracture of the right clavicle which was fixed using Ti LCP-SCP plate (Locking Compression Plate - Superior Clavicle Plate). ii) Another accident occurred after five months which resulted with the refracture of the right clavicle and bending of the osteosynthetic material requiring the reoperation of the patient again using the Ti LCP-SCP plate iii) After seven months, the patient arrived at the hospital indicating the pain in the right clavicle, whereas the fracture of the osteosynthetic material was detected. This last fracture was fixed again with Ti LCP-SCP plate in combination with two lag screws cross sectionally positioned.ConclusionWhereas second and third parts are focused on the complex evaluation of osteosynthetic material and the tissue observations of this medical case. The second part is focused on the evaluation of the osteosynthetic material and a its fractographical study. The third part of the case report is devoted to the microscopic analysis of the metal particles found in tissues in positions of the contacts with osteosynthetic material. |
Databáze: |
OpenAIRE |
Externí odkaz: |
|