Long-term follow-up of the AdVance ® /AdVanceXP ® sling. What are the surgeons’ impressions? What are the patients’?

Autor: Á. Rivero Guerra, E. Izquierdo Morejón, L. Reina Alcaina, T. Fernández Aparicio, V. Muñoz Guillermo, B. Miñana López, C. Carrillo George, I. Barceló Bayonas, A. Pardo Martínez, A. Rosino Sánchez, G. Hita Villaplana, A. Romero Hoyuela, B. Pietricica
Rok vydání: 2018
Předmět:
Zdroj: Actas Urológicas Españolas (English Edition). 42:185-190
ISSN: 2173-5786
Popis: OBJECTIVES To analyse the safety, efficacy and quality of life of patients with male stress urinary incontinence after radical prostatectomy treated with the AdVance® and AdvanceXP® slings. PATIENTS AND METHOD The study included 92 patients with stress urinary incontinence after radical prostatectomy treated with the AdVance® and AdVanceXP® sling between May 2008 and December 2015. A perineal repositioning test was performed in all cases with sphincter coaptation of≥1.5cm. Mild stress urinary incontinence was defined as the use of 1-2 absorbers/24h; moderate was defined as 3-5 absorbers/24h; and severe was defined as more than 5 absorbers/24h. Healing was defined as the total absence of using pads; improvement was defined as a reduction>50% in the number of pads; and failure was defined as a reduction
Databáze: OpenAIRE