Autor: |
Emilio Ruiz Morales, Ying Cao, Michiel Steyaert, Carlo Damiani, Wouter De Cock, Richard Meek, Ludo Vermeeren, Marco Van Uffelen, Paul Leroux, Jens Verbeeck, Bernhard Haist, Roberto Ranz Santana, Laura Mont Casellas |
Rok vydání: |
2015 |
Předmět: |
|
Zdroj: |
2015 15th European Conference on Radiation and Its Effects on Components and Systems (RADECS). |
DOI: |
10.1109/radecs.2015.7365579 |
Popis: |
This paper shows a customized MGy radiation tolerant instrumentation amplifier. The 65 nm CMOS-based ASIC amplifier has an offset smaller than 1 µV and a noise level below 50 nV/√Hz from DC. It consumes less than 5 mW and has a common-mode-rejection-ratio larger the 100 dB. In addition, it allows a programmable gain setting from 8,16,32,64,128 to 256. The performance of this instrumentation amplifier was monitored during an on-line radiation experiment up to a total ionizing dose larger than 1 MGy, enabling the read-out of the most common nuclear temperature and position sensors. |