Autor: A. N. Skrinskii, Mikhail Yurkov, N. I. Balalykin, E. M. Syresin, V. V. Kobets, E.I. Antokhin, V. G. Kadyshevskii, R. Maas, N.A. Mezentsev, P.D. Voblyi, H. Lux, V. V. Mikhailin, I. V. Titkova, V. N. Kolobanov, Grigori Shirkov, H. van Middelkop, G. I. Sidorov, Igor Meshkov, P. F. Beloshitskii, Nikolay Morozov, G.N. Kulipanov, J. Spelt, A. Sisakyan, Evgeny Levichev
Rok vydání: 2001
Předmět:
Zdroj: Atomic Energy. 91:841-849
ISSN: 1063-4258
DOI: 10.1023/a:1013852407873
Popis: An accelerator complex DELSI (Dubnen Electron Synchrotron) is planned for constuction as source of synchrotron radiation with high brightness in a wide spectral range – from far infrared (100 μm) up to high-energy x-ray (50 keV). This will make it possible to perform a wide range of research at the Joint Institute of Nuclear Research. The DELSI complex includes a linear electron accelerator up to energy 800 MeV and a storage ring with a 136 m perimeter at 1.2 GeV, in which a 10 T wiggler and an undulator (0.75 T, 150 periods) are built-in. The linear electron accelerator of the DELSI complex will be used for injection and for producing free-electron lasers. The parameters of synchrotron radiation from the bending magnets and built-in devices of the DELSI complex, the magnetic structure of the storage ring with the wiggler and undulator switched off, the effect of built-in devices on the ring optics, and the effect of errors on the closed orbit are examined; the synchrotron radiation parameters are briefly described.
Databáze: OpenAIRE