Calculation of the Unified Glare Rating based on luminance maps for uniform and non-uniform light sources

Autor: Peter Bracke, Geert Deconinck, Peter Hanselaer, Gertjan Scheir, Wouter Ryckaert
Rok vydání: 2015
Předmět:
Zdroj: Building and Environment. 84:60-67
ISSN: 0360-1323
DOI: 10.1016/j.buildenv.2014.10.027
Popis: In Europe, discomfort glare for interior lighting installations is assessed with the Unified Glare Rating (UGR). UGR is valid for a wide range of uniform light sources but the assessment of discomfort glare from non-uniform luminaires with current glare indices is questioned. LED luminaires often exhibit a non-uniform luminance distribution with alternating areas of high and low luminance. With a growing market share of LED luminaires for interior lighting, a better assessment of discomfort glare from non-uniform light sources becomes essential. In the present paper, the UGR formula is calculated alternatively from the luminance distribution. Individual pixels of a luminance map can be considered as individual light sources or they can be combined to form larger sources. For uniform light sources, the UGR is independent of the division of the luminance map. For non-uniform light sources, the UGR value is strongly dependent on the combination of the individual pixels and differences of up to 17.3 UGR units for the same luminaire are obtained. The UGR calculated from luminance maps is compared with the original UGR from the luminous intensity distribution and the UGR developed for small light sources. In conclusion, the assessment of discomfort glare from non-uniform light sources with UGR calculated from luminance maps is questioned.
Databáze: OpenAIRE