Neuroport® makes brain biopsy less invasive and easy even in eloquent areas
Autor: | Kenji Miki, Naoki Noguchi, Tetsuhisa Yamada, Megumu Mori, Yasutoshi Kai, Yoshihiro Natori |
---|---|
Rok vydání: | 2019 |
Předmět: |
medicine.medical_specialty
medicine.diagnostic_test business.industry Brain biopsy Less invasive General Medicine 03 medical and health sciences 0302 clinical medicine Eloquent cortex Modified Rankin Scale 030220 oncology & carcinogenesis Needle biopsy Biopsy medicine Tissue diagnosis Surgery Neurology (clinical) Radiology business 030217 neurology & neurosurgery |
Zdroj: | British Journal of Neurosurgery. :1-3 |
ISSN: | 1360-046X 0268-8697 |
DOI: | 10.1080/02688697.2019.1630557 |
Popis: | Tissue diagnosis of brain tumours in eloquent is often done via needle biopsy but this method yields small samples that may not be representative of the whole tumour. The Neuroport® system enables a larger tumour biopsy to be taken via a burr hole. We report our experience on 5 cases October 2017 and June 2018. Brainlab® navigation was used. The diagnosis in all patients was made without worsening of their modified Rankin scale scores. |