Pressure relief consideration for refrigeration equipment

Autor: Joseph C. Leung
Rok vydání: 1996
Předmět:
Zdroj: Process Safety Progress. 15:66-73
ISSN: 1547-5913
1066-8527
DOI: 10.1002/prs.680150204
Popis: Pressure relief sizing for refrigeration equipment is considered in this paper. In particular the ASHRAE fire sizing formula [2] is critically examined and comparisons are made with methods employed in other engineering institutes. The traditional sizing approach based on vapor relief is re-exmained in light of the recent findings from the DIERS (Design Institute for Emergency Relief Systems) work [11]. The occurrence of two-phase discharges during relief may result in significant overpresurization of the refrigeration equipment. The purpose of this paper is to suggest a methodology adequate for most designs and which has been verified with available experimental data.
Databáze: OpenAIRE