Performance of a Mixed Flow Pump with Varying Tip Clearance: Part 1
Autor: | TK Saha, S Soundranayagam |
---|---|
Rok vydání: | 1996 |
Předmět: |
geography
Angular momentum geography.geographical_feature_category Materials science 020209 energy Mechanical Engineering Specific speed Flow (psychology) Energy Engineering and Power Technology Mechanical engineering 02 engineering and technology Mechanics Classification of discontinuities Inlet Volumetric flow rate Tip clearance 020303 mechanical engineering & transports 0203 mechanical engineering 0202 electrical engineering electronic engineering information engineering Casing |
Zdroj: | Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy. 210:305-318 |
ISSN: | 2041-2967 0957-6509 |
Popis: | Measurements of the three-dimensional flow field entering and leaving a mixed flow pump of non-dimensional specific speed k = 1.89 [ Ns = 100 r/min (metric)] are discussed as a function of flowrate. Flow reversal at inlet at reduced flows is seen to result in abnormally high total pressures in the casing region, but causes no noticeable discontinuities on the head-flow characteristics. Inlet prerotation is associated with the transport of angular momentum by the reversal eddy and begins with the initiation of flow reversal. |