Popis: |
Corrosion tests were conducted on A-516 and A-537 carbon steel in simulated Double Shell Slurry, Future PUREX, and Hanford Facilities wastes. The corrosion rate data, gathered between 25 and 180/sup 0/C, were statistically ''modeled'' for each waste; a fourth model was developed that utilized the combined data. The report briefly describes the modeling procedure and details on how to access information through a computerized data system. Copies of the report and operating information may be obtained from the author (DB Mackey) at 509-376-9844 of FTS 444-9844. |