CO2-heat pump water heater: characteristics, system design and experimental results

Autor: Petter Nekså, G. Reza Zakeri, Havard Rekstad, Per Arne Schiefloe
Rok vydání: 1998
Předmět:
Zdroj: International Journal of Refrigeration. 21:172-179
ISSN: 0140-7007
DOI: 10.1016/s0140-7007(98)00017-6
Popis: CO 2 is one of the few non-toxic and non-flammable working fluids that do not contribute to ozone depletion or global warming, if leaked to the atmosphere. Tap water heating is one promising application for a trans-critical CO 2 process. The temperature glide at heat rejection contributes to a very good temperature adaptation when heating tap water, which inherits a large temperature glide. This, together with efficient compression and good heat transfer characteristics of CO 2 , makes it possible to design very efficient systems. A heating-COP of 4.3 is achieved for the prototype when heating tap water from 9°C to 60°C, at an evaporation temperature of 0°C. The results lead to a seasonal performance factor of about 4 for an Oslo climate, using ambient air as heat source. Thus, the primary energy consumption can be reduced with more than 75% compared with electrical or gas fired systems. Another significant advantage of this system, compared with conventional heat pump water heaters, is that hot water with temperatures up to 90°C can be produced without operational difficulties.
Databáze: OpenAIRE