Autor: J. Jolie, Petra Kudejova, S. Baechler, J.-L. Schenker
Rok vydání: 2003
Předmět:
Zdroj: Journal of Radioanalytical and Nuclear Chemistry. 256:239-245
ISSN: 0236-5731
DOI: 10.1023/a:1023977015725
Popis: The k0-standardization method has been applied and evaluated at the cold-neutron prompt gamma-ray activation (PGA) facility of the Swiss spallation source SINQ (Paul Scherrer Institute). The k0-factors for 26 elements of interest were measured using chlorine as a comparator. The results showed good agreement with the values determined at other cold and thermal neutron guided beams, except for a few elements. Then, standard reference materials were analyzed to assess the accuracy of the method using the obtained k0-factors. Finally, the technique was used for multielement determination in various samples coming from nuclear waste storage, geochemistry and geology. In addition, the non-destructive nature of PGAA offered an interesting application in archeology.