Computertomographie bei der Diagnose von Komplikationen nach allogener Nierentransplantation
Autor: | B. Husberg, H. Treugut, Molde A, J. Hildell, U. Nyman |
---|---|
Rok vydání: | 1982 |
Předmět: |
medicine.medical_specialty
medicine.diagnostic_test business.industry Infarction Computed tomography urologic and male genital diseases medicine.disease Collection system Surgery Contrast medium medicine.anatomical_structure Urine leakage medicine Renal allograft Radiology Nuclear Medicine and imaging business Renal pelvis |
Zdroj: | RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren. 136:138-143 |
ISSN: | 1438-9010 1438-9029 |
DOI: | 10.1055/s-2008-1056015 |
Popis: | Computed tomography was used in a consecutive series of 74 transplantations in the diagnosis of complications to renal allograft surgery. Thirty-nine peritransplant fluid collections were demonstrated, 13 of these were subjected to surgery. A diagnosis of the specific nature of the fluid collection was possible in cases of urine leakage and fresh hematomas. The method was sensitive in defining the size of the renal pelvis though differentiation between postrenal obstruction and large non-obstructed collecting system was not always possible. The cause of postrenal obstruction could be identified in 5 patients out of 10. Renal infarctions were diagnosed in 8 patients. Computed tomography seems to be a highly accurate method in the diagnosis of complications to renal allograft surgery. The method can be used independent of transplant function and the use of contrast medium is necessary only to verify urine leakage and infarction. |
Databáze: | OpenAIRE |