Comparison of hot embossing micro structures with and without ultrasound

Autor: Johannes Sackmann, Wei Zou, Matthias Worgull, Werner Karl Schomburg, Andreas Striegel
Rok vydání: 2019
Předmět:
Zdroj: Microsystem Technologies. 25:4185-4195
ISSN: 1432-1858
0946-7076
DOI: 10.1007/s00542-019-04469-1
Popis: Hot embossing with and without ultrasound are compared in this paper with respect to several properties of the fabricated samples. The same mold was employed for both processes and process parameters have been chosen adapted to each process such that to the best knowledge of the authors good moldings were achieved. Shrinkage is similar for both processes. Better mold filling is achieved without ultrasound and the polymer structures correspond better to the mold after demolding. Undesired sample curvature is also much less. With ultrasound required investment costs and energy consumption are significantly less, and the cycle time is reduced to seconds.