Leningrad NPP-2 start-up loss of power test and its simulation with use of KORSAR/GP code
Autor: | I. G. Petkevich, M. A. Uvakin, M. V. Suslov |
---|---|
Rok vydání: | 2019 |
Předmět: |
Nuclear and High Energy Physics
Radiation Computer science 020209 energy Nuclear engineering 02 engineering and technology Start up 01 natural sciences 010305 fluids & plasmas Test (assessment) Nuclear Energy and Engineering Power test 0103 physical sciences 0202 electrical engineering electronic engineering information engineering Code (cryptography) General Materials Science VVER Safety Risk Reliability and Quality |
Zdroj: | Kerntechnik. 84:302-308 |
ISSN: | 2195-8580 0932-3902 |
DOI: | 10.3139/124.190026 |
Popis: | The paper deals with the results of the Leningrad NPP-2 start-up loss of power test and its simulation with use of KORSAR/GP code. The test was held at the 1st unit with VVER 1200 reactor on the 29th of March. During the test the steam generators were refilled with EFW system at first. This system is connected to the SG steam space. Therefore, injection of water leads to the secondary pressure decrease. This phenomenon is difficult for simulation due to complicated structure of the SG internals. Also, the test provides unique data for the reactor facility cooldown at natural circulation in the primary circuit. The important data for reactor head and pressurizer cooldown were obtained. Thus, the test data provides the validation of several processes such as: emergency feedwater injection into the steam generator; steam generator filling with “cold” water from AFWS; pressure regulation at filled pressurizer; cooldown of the reactor head and the coolant circulation beneath the head. The results of the test were used for the validation of KORSAR/GP code, unit nodalization and equipment models. |
Databáze: | OpenAIRE |
Externí odkaz: |