Popis: A portable hard x-ray source has been developed for nondestructive testing, medical imaging, and flash x-ray radiography. The source is powered by a Marx generator that produces a 200 kV, 1.2 kA pulse of 60 ns full width at half maximum. The x-ray tube is composed of a tungsten anode and a mesh cathode. The time dependence of the voltage, current, and x-ray emission were measured and were in good agreement with computer simulations. The simulation model accounted for the 15 capacitors and 15 spark gap switches of the Marx generator and the perveance of the electron flow across the anode–cathode gap. The simulations indicated that the 5 J energy that was stored in the Marx generator was efficiently delivered to the x-ray tube. The measured x-ray exposure, 34 mR at a distance of 30 cm, was in good agreement with the calculated exposure. X-ray images are presented that demonstrate the capabilities of the x-ray source for medical imaging, nondestructive testing, and flash x-ray radiography.