Metrological Assessment of Infrared Tympanic Thermometers: A Safety Measure
Autor: | Cecília M. P. Rodrigues, Sílvia Moutinho, Humberto S Machado, Ana Luisa Silva, Cláudia Pereira, Idalina Beirão |
---|---|
Rok vydání: | 2016 |
Předmět: |
Measure (data warehouse)
medicine.medical_specialty 030504 nursing Infrared business.industry Acoustics Core temperature Surgery Metrology 03 medical and health sciences 0302 clinical medicine medicine 030212 general & internal medicine 0305 other medical science business Tympanic thermometers Paediatric patients |
Zdroj: | Journal of Pregnancy and Child Health. |
ISSN: | 2376-127X |
DOI: | 10.4172/2376-127x.1000240 |
Popis: | Background: There are different temperature readings in different body sites that are estimated values of the core temperature. The IR tympanic thermometers measure the thermal radiation of the tympanic membrane. These devices are often considered the best non-invasive and most accurate technique to measure body temperature. The incorrect use and the features of the IR tympanic thermometers may lead to significant errors in temperature readings. A metrological approach allows the analysis of the accuracy of the IR tympanic thermometers when compared to a standard electronic device. The main purpose of this study was to assess the measuring errors of the infrared (IR) tympanic thermometers over time and to decide the best time interval between metrological assessments. Methods: The metrological control of IR tympanic thermometers (n=125 used in adult and n=21 in paediatric patients) was based on the comparison with a thermal imaging black body device. An acceptance criterion (AC) of ±0.2°C was considered for metrological control. Results: 93.90% of the errors of low temperature readings (32°C) and 94.24% of the errors of high temperature readings (40°C) were within the acceptance criterion (±0,2°C). Results show 6% of the errors out of specifications. The maximum and minimum errors were +2.5°C and –0.8°C and +0.8°C and -5.2°C for low and high temperatures, respectively. For high temperatures the errors decrease gradually over time unlike to the observed regarding the low temperatures. Conclusions: The variability of errors might be device related; nevertheless it does not preclude its reliability. Significant errors were not found. The accuracy of the IR tympanic thermometers improved over time for high temperatures. Regular metrological assessments are needed to identify errors and assure a good performance of the IR tympanic thermometers. |
Databáze: | OpenAIRE |
Externí odkaz: |