Investigation of precision, accuracy and confidence of X-ray diffraction for determining crystallite size in nanopowders
Autor: | Rodriguez, Patrick F Fleig, Martin B. Nemer, H.W. Papenguth, Christine Cardinal Roberts, Alexander P. Moore |
---|---|
Rok vydání: | 2021 |
Předmět: |
Diffraction
Accuracy and precision Materials science Scanning electron microscope Analytical chemistry Inverse transform sampling 02 engineering and technology 010402 general chemistry 021001 nanoscience & nanotechnology 01 natural sciences General Biochemistry Genetics and Molecular Biology 0104 chemical sciences Characterization (materials science) X-ray crystallography Confidence distribution Crystallite 0210 nano-technology |
Zdroj: | Journal of Applied Crystallography. 54:856-866 |
ISSN: | 1600-5767 |
DOI: | 10.1107/s1600576721002922 |
Popis: | X-ray diffraction (XRD) is often utilized as a method of determining bulk sample crystallite size in powder characterization. While it is generally accepted that XRD peak broadening allows for qualitative crystallite size comparisons, its use for quantitative information is still debated. This study investigates the quantitative capability of XRD for determining the crystallite sizes of magnesium oxide nanocrystals by examining the precision, accuracy and uncertainty using the whole pattern (WP) weighted least-squares and Williamson–Hall (WH) methods. The precision of the methods was investigated by re-preparing, re-running and re-analysing identical samples. Both methods were found to be precise within 2 nm. The accuracy of the methods was investigated by comparing them against independent crystallite size analyses using visual particle identification from scanning electron microscopy micrographs and from indirect calculations using Brunauer–Emmett–Teller (BET) adsorption-determined surface areas. The WP method was found to be more accurate than the WH method, which consistently underpredicted the crystallite size. Finally, the confidence of the methods was investigated using a Bayesian inference statistical inversion method. The WP method was found to have a narrower confidence distribution in its crystallite size determination than the WH method. The broad WH confidence indicates that reliable quantitative single-measurement crystallite size determinations are not feasible using the WH technique. However, the WP method demonstrated precision, accuracy and confidence, allowing quantitative crystallite size determinations to be made. |
Databáze: | OpenAIRE |
Externí odkaz: |