Feasibility test of the concept of long-term passive cooling system of emergency cooldown tank

Autor: Youngmin Bae, Joo Hyung Moon, Young-In Kim, Myoung Jun Kim, Hee Joon Lee
Rok vydání: 2015
Předmět:
Zdroj: Annals of Nuclear Energy. 80:403-408
ISSN: 0306-4549
Popis: When a passive cooling system is activated in the accident of a nuclear reactor, the water in the emergency cooldown tank of that system will eventually be fully depleted by evaporation. If, however, the evaporating water could be returned to the tank through an air-cooled condensing heat exchanger mounted on top of the tank, the passive cooling system could provide cooling for an extended period. This feasibility of new concept of long-term passive cooling with an emergency cooldown tank was tested by performing an energy balance test with a scaled-down experimental setup. As a result, it was determined that a naturally circulating steam flow can be used to refill the tank. For an air-cooled heat exchanger, the cooling capacity and air-side natural convective heat transfer coefficient were obtained to be 37% of the heat load and between 9 and 10.2 W/m 2 /K depending on the heat load, respectively. Moreover, it was clearly verified that the water level in the emergency cooldown tank could be maintained over the long-term operation of the passive cooling system.
Databáze: OpenAIRE