Evacuated heat pipe solar collector

Autor: F. Mahdjuri
Rok vydání: 1979
Předmět:
Zdroj: Energy Conversion. 19:85-90
ISSN: 0013-7480
DOI: 10.1016/0013-7480(79)90004-4
Popis: A tubular evacuated solar collector with rectangular performance characteristics is introduced. The heat transfer from the absorber plate with selective coating to the water tubing occurs via a heat pipe system. In order to avoid any delay in the operation of the heat pipe due to superheating of the vapour, we have introduced a trap mechanism for the condensed liquid. To avoid the disadvantage of the high no-load condition of the vacuum collectors we have used the physical features of the critical point of the heat pipe working fluid. Above the critical temperature, T c of the working fluid the condensation effect will disappear. This means that above T c the heat transfer property of a heat pipe will vanish. This will cause only a slight increase of the condenser temperature above T c of the liquid used. For our heat pipe system we have chosen working liquids with critical temperature between 95–115°C.