Anodic Behavior of Specimens Prepared From a Full-Diameter Alloy 22 Fabricated Mockup Container for Nuclear Waste
Autor: | John C. Estill, Raul B. Rebak |
---|---|
Rok vydání: | 2006 |
Předmět: | |
Zdroj: | Journal of Pressure Vessel Technology. 129:729-736 |
ISSN: | 1528-8978 0094-9930 |
Popis: | Alloy 22 (N06022) has been extensively tested for general and localized corrosion behavior both in the wrought annealed condition and in the as-welded condition. In general, the specimens for laboratory testing are mostly prepared from flat plates of material. It is important to determine if the process of fabricating a container will affect the corrosion performance of this alloy. Thus, specimens for corrosion testing were prepared directly from a fabricated full-diameter Alloy 22 container. Results show that both the anodic corrosion behavior and the localized corrosion resistance of specimens prepared from a welded container were the same as those from flat welded plates. |
Databáze: | OpenAIRE |
Externí odkaz: |