The importance of BMI in dosimetry of 153 Sm-EDTMP bone pain palliation therapy: A Monte Carlo study
Autor: | Ali Asghar Parach, Faraz Kalantari, Maryam Fallahpoor, Mehrshad Abbasi |
---|---|
Rok vydání: | 2017 |
Předmět: |
medicine.medical_specialty
Radiation Dose calculation business.industry Monte Carlo method Radiation dose 153sm edtmp Imaging phantom 030218 nuclear medicine & medical imaging 03 medical and health sciences 0302 clinical medicine 030220 oncology & carcinogenesis medicine Dosimetry Radiology medicine.symptom Bone pain Nuclear medicine business Target organ |
Zdroj: | Applied Radiation and Isotopes. 124:1-6 |
ISSN: | 0969-8043 |
DOI: | 10.1016/j.apradiso.2017.02.044 |
Popis: | Using digital phantoms as an atlas compared to acquiring CT data for internal radionuclide dosimetry decreases patient overall radiation dose and reduces the required analysis effort and time for organ segmentation. The drawback is that the phantom may not match exactly with the patient. We assessed the effect of varying BMIs on dosimetry results for a bone pain palliation agent, 153Sm-EDTMP. The simulation was done using the GATE Monte Carlo code. Female XCAT phantoms with the following different BMIs were employed: 18.6, 20.8, 22.1, 26.8, 30.3 and 34.7 kg/m2. S-factors (mGy/MBq.s) and SAFs (kg−1) were calculated for the dosimetry of the radiation from major source organs including spine, ribs, kidney and bladder into different target organs as well as whole body dosimetry from spine. The differences in dose estimates from different phantoms compared to those from the phantom with BMI of 26.8 kg/m2 as the reference, were calculated for both gamma and beta radiations. The relative differences (RD) of the S-factors or SAFs from the values of reference phantom were calculated. RDs greater than 10% and 100% were frequent in radiations to organs for photon and beta particles, respectively. The relative differences in whole body SAFs from the reference phantom were 15.4%, 7%, 4.2%, −9.8% and −1.4% for BMIs of 18.6, 20.8, 22.1, 30.3 and 34.7 kg/m2, respectively. The differences in whole body S-factors for the phantoms with BMIs of 18.6, 20.8, 22.1, 30.3 and 34.7 kg/m2 were 39.5%, 19.4%, 8.8%, −7.9% and −4.3%, respectively. The dosimetry of the gamma photons and beta particles changes substantially with the use of phantoms with different BMIs. The change in S-factors is important for dose calculation and can change the prescribed therapeutic dose of 153Sm-EDTMP. Thus a phantom with BMI better matched to the patient is suggested for therapeutic purposes where dose estimates closer to those in the actual patient are required. |
Databáze: | OpenAIRE |
Externí odkaz: |