Damage to steam-generating tubes of low-pressure circuit of drum-type heat recovery boiler used in the PGU-450 combined-cycle unit at Severozapadnaya cogeneration plant
Autor: | I. I. Belyakov, V. I. Nikitin, V. I. Breus |
---|---|
Rok vydání: | 2009 |
Předmět: | |
Zdroj: | Thermal Engineering. 56:124-128 |
ISSN: | 1555-6301 0040-6015 |
DOI: | 10.1134/s0040601509020062 |
Popis: | The results of investigation into the nature of damage to tube bends of the low-pressure evaporator of the P-90 heat recovery boiler installed at the Severozapadnaya cogeneration plant are presented. It has been found that damage was caused by cavitation wear due to action of steam-water flow. |