Recorded test data are presented for Test S-06-1 of the Semiscale Mod-1 LOFT counterpart test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying an hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-06-1 was conducted from initial conditions of 15 568 kPa and 564 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact loop to simulate emergency core coolant injection in a PWR. The heater rods in the electrically heated core were operated at an axial peak power density which was 30% of the maximum peak power density (52.5 kW/m). |